ABSTRACT

Abstract Background: Atrial fibrillation (AF) ablation under uninterrupted warfarin use is safe and recommended by experts. However, there is some controversy regarding direct-acting oral anticoagulants for the same purpose. Objective: To evaluate the safety of AF ablation under uninterrupted anticoagulation with rivaroxaban. Methods: A series of 130 patients underwent AF radiofrequency ablation under uninterrupted rivaroxaban use (RIV group) and was compared to a control group of 110 patients under uninterrupted warfarin use (WFR group) and therapeutic International Normalized Ratio (INR). We analyzed death, rates of thromboembolic events, major and minor bleedings, activated clotting time (ACT) levels, and heparin dose in the procedure. The ablation protocol basically consisted of circumferential isolation of the pulmonary veins guided by electroanatomic mapping. It was adopted a statistical significance of 5%. Results: The clinical characteristics of the groups were similar, and the paroxysmal AF was the most frequent type (63% and 59%, RIV and WFR groups). A thromboembolic event occurred in the RIV group. There were 3 patients with major bleeding (RIV = 1 and WFR = 2; p = 0.5); no deaths. Basal INR was higher in the WFR group (2.5 vs. 1.2 ± 0.02; p < 0.0001), with similar basal ACT levels (123.7 ± 3 vs. 118 ± 4; p= 0, 34). A higher dose of venous heparin was used in the RIV group (9,414 ± 199 vs. 6,019 ± 185 IU; p < 0.0001) to maintain similar mean ACT levels during the procedure (350 ± 3 vs. 348.9 ± 4; p = 0.79). Conclusion: In the study population, AF ablation under uninterrupted rivaroxaban showed a safety profile that was equivalent to uninterrupted warfarin use with therapeutic INR.


Resumo Fundamento: A ablação de fibrilação atrial (FA) sob uso ininterrupto de varfarina é segura e recomendada por especialistas. Entretanto, há controvérsia quanto aos anticoagulantes orais de ação direta para o mesmo fim. Objetivo: Avaliar a segurança em realizar ablação de FA sob anticoagulação ininterrupta com rivaroxabana. Métodos: Uma série de 130 pacientes foi submetida à ablação com radiofrequência da FA sob uso ininterrupto de rivaroxabana (grupo RIV) e comparada a um grupo-controle de 110 pacientes que a fizeram sob uso ininterrupto de varfarina (grupo VRF) e relação normatizada internacional (RNI) terapêutica. Analisamos morte, taxas de eventos tromboembólicos, de sangramentos maiores e menores, níveis do tempo de coagulação ativado (TCA) e dose de heparina no procedimento. O protocolo da ablação consistiu basicamente em isolamento circunferencial das veias pulmonares guiado por mapeamento eletroanatômico. Significância estatística de 5% foi adotada. Resultados: As características clínicas dos grupos foram semelhantes e a FA paroxística mais frequente (63% e 59%, grupos RIV e VRF). Um evento tromboembólico ocorreu no grupo RIV. Foram três pacientes com sangramentos maiores (RIV = 1 e VRF = 2; p = 0,5); nenhum óbito. A RNI basal foi maior no grupo VRF (2,5 vs. 1,2 ± 0,02; p < 0,0001), com níveis de TCA basal semelhantes (123,7 ± 3 vs. 118 ± 4; p = 0,34). Maior dose de heparina venosa foi utilizada no grupo RIV (9.414 ± 199 vs. 6.019 ± 185 UI; p < 0,0001) para manter níveis médios de TCA semelhantes durante o procedimento (350 ± 3 vs. 348,9 ± 4; p = 0,79). Conclusão: Na população estudada, a ablação de FA sob rivaroxabana ininterrupta teve segurança equivalente à varfarina ininterrupta, com RNI terapêutica.


Subject(s)
Humans , Atrial Fibrillation , Catheter Ablation , Warfarin , Treatment Outcome , Rivaroxaban , Anticoagulants
4.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 30(2): f:51-l:54, abr.-jun. 2017. ilus
Article in Portuguese | LILACS | ID: biblio-848026

ABSTRACT

Paciente do sexo masculino, de 62 anos de idade, com megacólon chagásico sem manifestações cardíacas, apresentou evento sincopal sem pródromos, sendo submetido a Holter de 24 horas, ecocardiografia, teste ergométrico e cineangiocoronariografia, que se mostraram normais. O estudo eletrofisiológico mostrou ausência de distúrbios de condução e de indução de taquiarritmias. Durante a fase basal do teste de inclinação, o paciente apresentou taquicardia ventricular polimórfica. Foi realizado implante de cardioversor-desfibrilador implantável. Na evolução, apresentou deterioração da função ventricular com início de terapêutica específica. Após sete anos de acompanhamento, observaram-se três episódios de taquicardia ventricular polimórfica adequadamente revertidos pelo cardioversor-desfibrilador implantável


A 62 year-old man with Chagasic megacolon without cardiac manifestations developed a syncope without prodrome and was submitted to 24-hour Holter monitoring, echocardiogram, exercise test and coronary angiography. Electrophysiology tests showed there was no conduction and tachyarrhythmia induction disorders. During the baseline phase of the tilt test, the patient presented a polymorphic ventricular tachycardia. An implantable cardioverter defibrillator was implanted. At the follow-up, the patient presented left ventricular deterioration and specific therapy was started. After seven years of follow-up, three episodes of polymorphic ventricular tachycardia were observed and were successfully converted


Subject(s)
Humans , Male , Middle Aged , Chagas Disease/diagnosis , Tachycardia, Ventricular/complications , Tachycardia, Ventricular/diagnosis , Tilt-Table Test/methods , Defibrillators, Implantable , Echocardiography/methods , Electrocardiography/methods , Electrophysiologic Techniques, Cardiac/methods , Exercise Test/methods , Syncope/diagnosis , Treatment Outcome , Ventricular Function, Left